LCN 8310-804-1, Sensor, Door Mount, Safety
8310-804-1 (1) Door Mount Safety Sensor for Leading Edge
• Contains one active sensor module to detect
obstruction(s) on leading edge of door
• Use with Senior Swing will require 8310-847 Door Mount
Harness
To promote health and well-being, many facilities are now replacing traditional push buttons with touchless actuators. When a pedestrian waves his or her hand in front of the wall plate, the technology senses the motion and acknowledges intent to enter. No contact with an actuator, door hand, push bar or door is required.
Heavy Duty Touchless Actuators
- Flush mounted design: aesthetically pleasing and less susceptible to accidental damage
- Stainless steel construction: for rugged performance in harsh environments
- IP65 rated: to protect electronic components from water and cleaning liquids
- Customizable features: Visual and audible signaling
Standard Touchless Actuators
- Flush mounted design: aesthetically pleasing and less susceptible to accidental damage
- Silent activation: ideal for applications that seek to limit noise emission
- Variety of colors and form factors: available in black or white for single gang, double gang, jamb and round mounting styles
- Single and double gang face plates ship as pair
Close Proximity Touchless Actuators
- Short-range detection zone: reduces unwanted activation
- Flush mounted design: aesthetically pleasing and less susceptible to accidental damage
- Feedback: includes illuminated edges and audible signaling
- Learn cycle: simplifies setup
Harsh Conditions Touchless Actuators
- NEMA 4/IP65 rated enclosure: for rugged and durable performance
- Designed for harsh environments: including outdoor applications
- Customizable detection zone: for flexibility and ease of use
Battery Powered touchless actuators
- Battery-powered solutions to simplify touchless actuator installation and retrofit upgrades
- Various form factor options for a variety of applications
- Compatible with existing LCN transmitters and receivers
- AA battery powered
- Can be used in conjunction with RF devices for a completely wireless experience
- 8310-2210 kitted option available with all necessary components included and RF hardware pre-programmed
TECHNICAL SPECIFICATIONS
|
Power supply: |
12 – 24 VAC/VDC ±10% |
||
|
Current consumption: |
Master: on = 60 mA max. off = 30 mA max. |
Slave: on = 40 mA max. off = 30 mA max. |
|
|
Inhibit input: |
12 – 24 VAC/VDC ±10% (inhibited when voltage is applied) |
||
|
Monitoring request input: |
12 – 35 VDC required (polarity-sensitive) min. pulse width duration = 50 ms |
||
|
Output interface; relay: |
relay – max. contact rating: 1A @ 30v (resistive) |
||
|
Detection range: |
0 – 8’ |
||
|
Distance adjustment: |
2 – 8’ (rotating cam w/linear adjustment) |
||
|
Max. mounting height: |
8’ |
||
|
Detection time: |
< 50 ms |
||
|
Detection signal duration: |
Infinite Presence Detection |
||
|
Output hold time: |
Potentiometer range: 0.1 – 4.5 seconds |
||
|
Operating temperature range: |
-30 – 140 °F |
||
|
PCB dimensions: |
Master: 10.91” x 1.5” |
Slave: 8.75” x 1.5” |
|
|
Connector to door controller: |
8-position screw terminal on Master PCB |
||
|
Master-to-slave connection: |
flat-ribbon cable w/connectors and key lock |
||
|
Max. number of slaves: |
8 |
||
|
Functions selection: |
Detection mode: NO or NC Normal mode or Background Analysis mode |
||
Fast & Reliable Same Day & Expedited Shipping Available!